Per Koch Bulletin PB-798-3, the Koch KDF 600 Diffusion Media Cut Blanket is a bonded synthetic diffusion media designed for use in downdraft type spray booths where superior fractional efficiency and controlled laminar airflow is required for blemish-free finishes. Per Koch PB-798-3, KDF 600 utilizes a progressively dense fiber matrix enhanced with a specially formulated adhesive coating to provide exceptional performance in surface finishing operations. Per Koch PB-798-3, this formula prevents particle migration and creates unparalleled holding capacity, superior to other diffusion medias.
Per Koch PB-798-3, KDF 600 will improve FIRST PASS CAPABILITY and REDUCE REJECTS, which improves overall operational efficiency, saving time and money. Initial efficiency ratings of 99.9% at 5 microns and 100% at 10 microns make the KDF 600 ideally suited to provide world-class filtration for surface finishing operations.
What you get: pre-cut diffusion blankets sized for downdraft ceiling filter banks
Each variant is a single pre-cut blanket sized to fit specific downdraft booth ceiling filter bank panel dimensions — you don't cut these on-site like a bulk roll. Each variant ships at the exact factory-cut dimensions shown. The price you see for each variant is the per-blanket price. Available sizes:
- 35″x36″ (8.8 sq ft) — single pre-cut blanket
- 35″x72″ (17.5 sq ft) — single pre-cut blanket
- 45″x96″ (30.0 sq ft) — single pre-cut blanket
- 45″x120″ (37.5 sq ft) — single pre-cut blanket
- 47″x60″ (19.6 sq ft) — single pre-cut blanket
- 47″x100″ (32.6 sq ft) — single pre-cut blanket
- 60″x84″ (35.0 sq ft) — single pre-cut blanket
- 80″x84″ (46.7 sq ft) — single pre-cut blanket
- 80″x108″ (60.0 sq ft) — single pre-cut blanket
For non-standard booth dimensions, custom-cut orders, or facility-scale quantities, request a quote with your booth ceiling filter bank dimensions.
KDF 600 construction and specifications (per Koch PB-798-3)
- Product family: KDF 600 Diffusion Media (Koch Filter Corporation)
- Form factor: Cut Blanket
- Construction: 100% bonded synthetic media with tackifier (per Koch PB-798-3)
- Fiber matrix: Progressively dense fiber matrix (per Koch PB-798-3)
- Adhesive coating: Specially formulated adhesive coating that prevents particle migration and creates holding capacity superior to other diffusion medias (per Koch PB-798-3)
- Basis weight: 580 gsm (per Koch PB-798-3)
- Test air flow: 400 CFM (per Koch PB-798-3)
- Initial pressure drop: 0.21″ w.g. @ 100 FPM (per Koch PB-798-3)
- Recommended final resistance: 1.0″ w.g. (per Koch PB-798-3)
- Fractional efficiency @ 5 microns (initial): 99.9% (per Koch PB-798-3)
- Fractional efficiency @ 10 microns (initial): 100% (per Koch PB-798-3)
- Designed for: Downdraft spray booths requiring controlled laminar airflow for blemish-free finishes (per Koch PB-798-3)
About diffusion media in downdraft spray booths
Diffusion media is installed at the ceiling of a downdraft spray booth — the air-intake side, opposite the exhaust filter bank. Conditioned booth air enters through this layer of diffusion media before passing over the painted surface. KDF 600's job is twofold:
- Final particulate capture before paint contact: Even with pre-conditioned makeup air, fine particulates (5 microns and below) can carry into the booth and land on a wet finish — the cause of fish-eyes, dust nibs, and other rejects. Per Koch PB-798-3, KDF 600's 99.9% efficiency at 5 microns captures these particles before they reach the painted surface.
- Laminar airflow distribution: The progressively dense fiber matrix evenly distributes the airflow across the entire booth ceiling, so air moves down past the painted part in smooth parallel streamlines — not turbulent eddies. This prevents overspray rebound and gives finishers the clean air pattern needed for high-quality refinish work.
Note: KDF 600 is intake-side diffusion media. For paint overspray collection at the booth exhaust, see the SprayStop family of paint arrestors.
Sizing and ordering notes
- Match the blanket dimensions to your booth's ceiling filter bank panels. Cut blankets are sized as Width x Length (e.g., 45″x96″).
- Each variant is a single pre-cut blanket. Order multiple blankets by adjusting the quantity at checkout.
- Need a non-standard size? Request a quote with your exact booth ceiling dimensions.
- Larger blankets ship as freight. 60″ and larger widths are oversized and ship LTL freight. Account for delivery time and freight handling on facility orders.
- Installation orientation: Per Koch PB-798-3, KDF 600 is installed at the air-intake side of the booth (ceiling on a downdraft booth). Refer to your booth manufacturer's documentation for specific installation procedure.
- Disposal: Follow your local hazardous waste regulations for paint-saturated media if KDF 600 is replaced after capture of paint particulates.
Koch product literature
Detailed product specifications and test data for KDF 600 Diffusion Media are published in Koch Bulletin PB-798-3: KDF 600 Diffusion Media Product Specification PDF (Koch Filter Corporation).
Commercial & facilities
Buying filters for a building?
Volume pricing on any size or MERV, plus recurring delivery schedules. We handle facilities and commercial orders daily and can usually match or beat distributor pricing.
Paint spray booth filtration, sourced and shipped right
Auto body shops, collision centers, OEM finishing lines, woodworking finishing, aerospace, and industrial coating operations — the same family-founded HVAC filtration company that's been online since 2006, applied to paint booth media that has to perform under regulation.
Authorized Koch dealer
RememberTheFilter.com is an authorized dealer of Koch Filter paint arrestor products. Specs, performance data, and labeling reflect current Koch documentation — not a marketplace listing, not a relabeled import.
Genuine product, direct supply chain, no third-party sellers swapping inventory behind the listing.
Sized for the booths you actually run
Direct-fit and engineered replacements for Global Finishing Solutions, Col-Met, Garmat USA, Accudraft, Marathon, Binks, DeVilbiss, and JBI — the booth lineup most U.S. shops actually operate.
Custom sizes available for older booths, retrofits, and non-standard slot dimensions. Request a quote with your slot size and we'll confirm the fit.
Pallet, case, and PO-friendly
Standing rotation orders for collision shops, OEM finishing, government fleet maintenance, and industrial coating operations. Pallet quantities, scheduled delivery, net terms for established accounts, and full government/military buyer support.
W-9, COI, NDAA Section 889 documentation, tax-exempt setup, and PO/net terms available on request.
Direct-fit replacements for the major spray booth OEMs
Sized and engineered as direct-fit or engineered replacements for paint spray booths from these original equipment manufacturers:
Brand names referenced for compatibility purposes only. RememberTheFilter.com is not affiliated with the listed booth manufacturers unless explicitly stated. Customers are responsible for verifying booth filter slot dimensions and mounting requirements before ordering.
NESHAP compliance: 6H vs. 6X
Paint spray booth operations in the United States are regulated under the National Emission Standards for Hazardous Air Pollutants (NESHAP), codified in 40 CFR Part 63. The two subparts most relevant to spray booth filtration are Subpart 6H and Subpart 6X.
Auto Body & Miscellaneous Surface Coating
40 CFR Part 63 Subpart HHHHHH applies to auto body refinishing, collision repair, and miscellaneous surface coating of motor vehicles and mobile equipment.
Spray booth exhaust filtration must demonstrate paint overspray capture efficiency at the level required by the rule, with media tested under ASHRAE 52.1 or an equivalent EPA-recognized method.
Area Source Metal Fabrication & Finishing
40 CFR Part 63 Subpart XXXXXX applies to area-source metal fabrication and finishing operations, including spray painting of fabricated metal parts.
Compliance typically requires control of particulate hazardous air pollutants from spray application through filter-based capture systems verified for the specific coating operation.
Provided for general reference only and does not constitute regulatory or legal advice. The end user and facility operator are solely responsible for compliance with all applicable federal, state, and local air quality regulations. Filter selection for a regulated coating operation should be confirmed against the facility's air permit.
Standing rotation orders, scheduled delivery, PO terms.
Collision shops, OEM finishing lines, government fleet maintenance, and industrial coating operations order paint booth filtration from us in standing rotation. Pallet pricing, scheduled delivery to match production cycles, tax-exempt setup, and government/military buyer documentation available on request.
What customers say about Koch KDF 600 (Bonded Synthetic Diffusion Media for Downdraft Booths) Cut Blanket
Paint spray booth filtration questions
From sizing and NESHAP compliance to change-out cadence and pallet ordering — here's what booth operators ask before they buy. For product-specific specs, check the description above.
Browse the full paint spray booth filtration catalog
Intake (ceiling) filters capture inbound air contaminants before paint application; exhaust paint arrestors capture overspray downstream of the spray operation.
Authorized Koch Filter Dealer RememberTheFilter.com is an authorized dealer of Koch Filter paint arrestor products. Product specifications, performance data, and labeling reflect current manufacturer documentation at time of listing.
Verify Booth Filter Slot Dimensions Customers are responsible for verifying their paint spray booth's filter slot dimensions, frame depth, and any equipment-specific mounting requirements before placing an order. Booth manufacturers occasionally revise filter slot specifications between model years and production runs. When in doubt, measure the existing filter or consult the booth manufacturer's documentation prior to ordering.
Compliance Responsibility The end user and facility operator are solely responsible for compliance with all applicable federal, state, and local air quality regulations, including but not limited to NESHAP 40 CFR Part 63 Subpart HHHHHH (6H), Subpart XXXXXX (6X), state implementation plans, and local air district rules. RememberTheFilter.com supplies filtration products and general reference information; we do not provide regulatory determinations, permitting guidance, or legal advice. Filter selection for a regulated coating operation should be confirmed against the facility's air permit and applicable rules.
Not sure if Koch KDF 600 (Bonded Synthetic Diffusion Media for Downdraft Booths) Cut Blanket is the right fit for your booth?
Call, text, or email our team. Tell us your booth manufacturer, model, slot location, and the rule your facility operates under — we'll confirm the spec or set up a quote.